Mon - Fri: 9:00 a.m. - 6:00 p.m.
Language: EN | BM |
NEW-FLOW N-TYPE Variable Area Type Flowmeter (Rotameter)

Share:


NEW-FLOW N-TYPE Variable Area Type Flowmeter (Rotameter)

The NEW-FLOW N-TYPE Variable Area Flowmeter (Rotameter) provides direct local indication of gas or liquid flow. Process fluid passes through a tapered tube and raises the float until the variable flow area reaches equilibrium. Metal and plastic configurations, multiple flange ratings and a wide choice of flow ranges support chemical-process, water-treatment and general industrial flow applications.

Key Features

  • Variable-area measurement using a float and tapered tube
  • Configurations for gas and liquid service
  • Metal and plastic wetted-part options
  • Flanged connections from 10A to 125A
  • Optional normally-open alarm switch with one or two set points

Engineering Specifications

Specification Details
Measurement principle Variable area with float and tapered tube
Service Gas and liquid
Nominal sizes 10A, 15A, 20A, 25A, 32A, 40A, 50A, 65A, 80A, 100A and 125A
Liquid flow range 0.1–1.0 to 200–2,000 L/min, depending on size
Gas flow range 2–20 to 3,000–30,000 NL/min, depending on size
Maximum viscosity ≤3 cP
Accuracy ±2.5% of full scale
Maximum working temperature Metal construction: 100°C; plastic construction: 60°C
Maximum body pressure NS and NI: 15 kg/cm²; NV: 6 kg/cm²
Measuring-tube pressure Glass: 6 kg/cm² for 10A–50A, 5 kg/cm² for 65A–80A and 4 kg/cm² for 100A–150A; PC: 10 kg/cm², instantaneous pressure 15 kg/cm²
Wetted-part models NS: stainless steel; NI: steel; NV: plastic
Material options Body: SS304, SS316, SS316L, PVC, PP, PVDF or other options; indicator tube: glass or PC; float: SS304, SS316, PVC, PP, PVDF or Teflon; seals: NBR, Viton or Teflon
Flange ratings JIS 5K, JIS 10K, ANSI 150 or ANSI 300
Alarm switch Normally open; one set point, two set points or no alarm
Switch rating AC 125 V, 0.5 A; DC 100 V, 10 W; maximum DC 250 V, less than 1 mA

Selection note: Confirm the medium, flow range, size, pressure, temperature, wetted materials, indicator tube, float, seals, flange rating and alarm requirements before ordering.



 Inquiry - NEW-FLOW N-TYPE Variable Area Type Flowmeter (Rotameter)